| Number of signal periods | 100, 200, 250, 256, 400, 500, 512, 625, 800, 1000, 1024, 1250, 2000, 2048, 2500, 4000, 4096, 5000, 8000, 8192, 10000 |
| Commutation | | 0 | Without commutation | | 2 bis 32 | Number of commutation signal periods per revolution (number of motor pole pairs) |
|
| Shaft | | Metric | 3 mm, 4 mm, 5 mm, 6 mm, 8 mm | | Inch | 1/8, 1/8+, 3/16, 3/16+, 1/4, 1/4+, 5/16, 5/16+, 3/8, 3/8+ |
|
| Output signal | | LD | Square-wave signals with differential line driver as per RS-422 | | PP | Square-wave signals with push-pull driver output |
|
| Power supply | |
| Reference mark | | 1 | Width: 90° ±45° elec. Gate: Ua1 High and Ua2 High | | 6 | Width: 90° ±45° elec. Gate: Ua1 Low and Ua2 Low | | 7 | Width: 270° ±45° elec. Gate: Ua1 High and Ua2 High | | 8 | Width: 270° ±45° elec. Gate: Ua1 Low and Ua2 Low |
|
| PCB connector | |
| Flange and housing design | | C, SC* | Flange with ⌀ 32,5 mm mounting screw circle, closed housing | | H, SH* | Flange with ⌀ 32,5 mm mounting screw circle, housing with central hole | | C4, SC4* | Flange with ⌀ 46,0 mm mounting screw circle, closed housing | | H4, SH4* | Flange with ⌀ 46,0 mm mounting screw circle, housing with central hole | | CR, SCR* | Syncro flange, resolver size 15, closed housing | | HR, SHR* | Syncro flange, resolver size 15, housing with central hole |
|
| Flange fastening screws | |